  pic120.241d piano-series 24v, 5a, s ingle p hase i nput p ower s upply ? ac 100-120v / 200-240v auto-select input ? cost optimized without co mpromising quality or reliability. ? width only 39mm ? efficiency up to 92.3% ? full power between -10c and +55c ? dc-ok relay contact included ? 3 year warranty 1/22 g eneral d escription these piano series units are extraordinarily compact, industrial grade power su pplies that focus on the essential features needed in todays industrial applications. the excellent cost/performance ratio presents many new and exciting opportunities without compromising quality or reliability. the mechanically robust housing is made of a high- grade, reinforced molded material, which permits the units to be used in surrou nding temperatures up to 70c. the unit is equipped with a auto-select input voltage stage, which makes the unit suitable for global use. the addition of a dc-ok signa l makes the unit suitable for many industry applicat ions such as: process, automation and many other cr itical applications where preventive function monitoring can help to avoid long downtimes. s hort - form d ata output voltage dc 24v 24 - 28vdc adjustment range output for ac 110-120 / 220-240v mains: 5.0 - 4.3a 3.1 - 2.7a at 24-28v, <55c at 24-28v, <70c for ac 100 / 200v mains: 5.0 - 4.3a 2.5 - 2.1a at 24-28v, <50c at 24-28v, <70c output ripple < 100mvpp 20hz to 20mhz ac input voltage ac 100-120v / 200-240v 10% auto-select mains frequency 50-60hz 6% ac input current 1.72a / 1.05a at 120/ 230vac power factor 0.64 / 0.54 at 120/ 230vac ac inrush current 22a / 33a peak at 120/ 230vac, 40c efficiency 91.2% / 92.3% at 120/ 230vac losses 11.6w / 10.0w at 120/ 230vac temp. range -10c to +70c operational derating 3w/c +55 to +70c *) hold-up time 51ms / 50ms at 120/ 230vac dimensions 39x124x124mm wxhxd weight 370g / 0.81lb *) +50 to +70c for ac 100v / 200v mains o rder n umbers power supply pic120.241d 24-28v unit accessory yr2.diode redundancy module uf20.241 buffer module m arkings ind. cont. e q. ul 508 ul 60950-1 emc, lvd jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany
pic120.241d piano-series 24v, 5a, s ingle p hase i nput i ndex page page 1. intended use .......................................................3 2. installation requirements ...................................3 3. ac-input ...............................................................4 4. dc-input ...............................................................5 5. input inrush current ...........................................5 6. output .................................................................6 7. hold-up time .......................................................7 8. dc-ok relay contact ..........................................7 9. efficiency and power losses ................................8 10. lifetime expectancy and mtbf ...........................9 11. functional diagram .............................................9 12. terminals and wiring ........................................10 13. front side and user elements ...........................11 14. emc ....................................................................12 15. environment ......................................................13 16. protection features ...........................................14 17. safety features ..................................................14 18. dielectric strength ............................................15 19. approvals .......................................................... 16 20. rohs, reach and othe r fulfilled standards .. 16 21. physical dimensions and weight ..................... 17 22. accessory ........................................................... 18 22.1. uf20.241 buffer module ..........................18 22.2. yr2.diode redundancy module .............18 23. application notes ............................................. 19 23.1. peak current capability ...........................19 23.2. back-feeding loads ..................................19 23.3. external input protection .........................20 23.4. parallel use to increase output power ....20 23.5. parallel use for redundancy ....................20 23.6. series operation .......................................21 23.7. inductive and capacitive loads ................21 23.8. charging of batteries ...............................21 23.9. operation on two phases ........................22 23.10. use in a tightly sealed enclosure ............22 the information presented in this docume nt is believed to be a ccurate and reliable and ma y change without notice. no part of this document may be reproduc ed or utilized in any form without pe rmission in writing from the publisher. t erminology and a breviations pe and symbol pe is the abbreviation for p rotective e arth and has the same meaning as the symbol . earth, ground this document uses the term earth which is the same as the u.s. term ground. t.b.d. to be defined, value or de scription will follow later. ac 230v a figure displayed with the ac or dc before the value represents a nominal voltage with standard tolerances included. e.g.: dc 12v describes a 12v battery disregardi ng whether it is full (13.7v) or flat (10v) 230vac a figure with the unit (vac) at the end is a momentary figure without any additional tolerances included. 50hz vs. 60hz as long as not otherwise stated, ac 100v a nd ac 230v parameters ar e valid at 50hz mains frequency. ac 120v parameters are valid for 60hz mains frequency. may a key word indicating flexibility of choice with no im plied preference. shall a key word indicating a mandatory requirement. should a key word indicating flexibility of choi ce with a strongly pref erred implementation. jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 2/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 1. i ntended u se this device is designed for installation in an enclosure a nd is intended for the general professional use such as in industrial control, office, communicati on, and instrumentation equipment. do not use this power supply in equipment, where malfuncti on may cause severe personal injury or threaten human life. 2. i nstallation r equirements this device may only be installed and put into opera tion by qualified personnel. this device does not contain serviceable parts. the tripping of an internal fuse is caused by an internal defect. if damage or malfuncti on should occur during installation or operation, i mmediately turn power off and send unit to the factory for inspection. mount the unit on a din-rail so that the input terminals are located on the bottom of the unit. this device is designed for convection cooling and does not require an external fan. do not obstruct airflow and do not cover ventilation grid (e.g. cable conduits) by more than 15%! keep the following installation clearance s: 40mm on top, 20mm on the bottom, 5mm on the left and right sides are recommended when the device is loaded permanently with more than 50% of th e rated power. increase this clearance to 15mm in case the adjacent device is a heat source (e.g. another power supply). a disconnecting means shall be provided for the output of the power supplies when used in applications according to csa c22.2 no 107.1-01. warning risk of electrical shock, fi re, personal injury or death. - do not use the power supply without proper grounding (protective earth). us e the terminal on the input block for earth connection. - turn power off before working on the devi ce. protect against inad vertent re-powering. - make sure that the wiring is correct by following all local and national codes. - do not modify or repair the unit. - do not open the unit as high voltages are present inside. - use caution to prevent any foreign objects from enteri ng the housing. - do not use in wet locations or in areas wh ere moisture or condens ation can be expected. - do not touch during power-on, and immediatel y after power-off. hot surfaces may cause burns. jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 3/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 3. ac-i nput ac input nom. ac 100-120v / 200-240v auto-select, suitable for tn-, tt- and it mains networks ac input range min. 90-132vac / 180- 264vac continuous operation min. 264-300vac < 500ms allowed voltage l or n to earth max. 300vac continuous, iec 62103 input frequency nom. 50C60hz 6% external input protection see recommendations in chapter 23.3 . ac 100v ac 120v ac 230v input current typ. 2.0a 1. 72a 1.05a at 24v, 5a, see fig. 3-3 power factor *) typ. 0.66 0.64 0.54 at 24v, 5a, see fig. 3-4 crest factor **) typ. 2.7 2.8 3.4 at 24v, 5a turn-on voltage typ. 78vac 78vac 157vac at 24v 0a, steady-state value, see fig. 3-1 shut-down voltage typ. 68vac 68vac 68vac at 24v 5a, steady-state value, see fig. 3-1 start-up delay typ. 400ms 400ms 100ms see fig. 3-2 rise time typ. 30ms 30ms 30ms at 24v, 5a const. current load, 0mf load capacitance, see fig. 3-2 typ. 90ms 90ms 90ms at 24v, 5a const. current load, 5mf load capacitance,, see fig. 3-2 turn-on overshoot max. 200mv 200mv 200mv see fig. 3-2 *) the power factor is the ratio of the true (or real) power to the apparent power in an ac circuit. **) the crest factor is the mathematical ratio of the peak value to rms value of the input current waveform. fig. 3-1 input voltage range, typ. fig. 3-2 turn-on behavior, definitions turn-on 90 rated input ranges v in p out 264 180 shut-down 132 upper range lower range 300vac max. 500ms start-up delay rise time overshoot - 5% output voltage input voltage fig. 3-3 input current vs. output load at 24v fig. 3-4 power factor vs. output load 5a 0.5 1 1.5 2 2.5 3 3.5 4 4.5 0 0.3 0.6 0.9 1.2 1.5 1.8 2.2a input current, typ. b c a output current a) 100vac b) 120vac c) 230vac power factor, typ. 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5a 0.45 0.50 0.55 0.60 0.65 0.70 output current a) 100vac b) 120vac c) 230vac b c a jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 4/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 4. dc-i nput do not operate this power supply with dc-input voltage. 5. i nput i nrush c urrent a ntc inrush limiter limits the input inrush current after tu rn-on of the input voltage. ac 100v ac 120v ac 230v inrush current *) max. 23a peak 27a peak 40a peak 40c ambient, cold start typ. 18a peak 22a peak 33a peak 40c ambient, cold start typ. 13a peak 16a peak 30a peak 25c ambient, cold start inrush energy *) max. 0.4a 2 s 0.5a 2 s 1.5a 2 s 40c ambient, cold start *) the charging current into emi suppression capacitors is disregarded in the first microseconds after switch-on. fig. 5-1 input inrush current, typical behavior 230vac input, 24v 5a output, 40c ambient fig. 5-2 input inrush current, zoom into first peak 230vac input, 24v 5a output, 40c ambient 20ms/div input current 20a/div input voltage 500v/div output voltage 20v/div 1ms/div ipeak = 33a input current 10a/div jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 5/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 6. o utput output voltage nom. dc 24v adjustment range min. 24-28v guaranteed max. 30v **) at clockwise end position of potentiometer factory settings typ. 24.1v 0.2%, at full load, cold unit line regulation max. 10mv 90-132 / 180-264vac load regulation max. 150mv static value, 0a ? 5a ? 0a ripple and noise voltage max. 100mvpp 20hz to 20mhz, 50ohm output current for ac 110-120 / 220-240v mains voltages (includes ac 208v mains): nom. 5a at 24v, below +55c ambient temperature nom. 4.3a at 28v, below +55c ambient temperature nom. 3.1a at 24v, at +70c ambient temperature nom. 2.7a at 28v, at +70c ambient temperature derate linearly between +55c and +70c for ac 100 / 200v mains voltages: nom. 5a at 24v, below +50c ambient temperature nom. 4.3a at 28v, below +50c ambient temperature nom. 2.5a at 24v, at +70c ambient temperature nom. 2.1a at 28v, at +70c ambient temperature derate linearly between +50c and +70c overload behaviour continuous cu rrent output voltage > 10vdc, see fig. 6-1 intermittent output voltage < 10vdc, see fig. 6-1 short-circuit cu rrent typ. 3.5a *) average (r.m.s.) current, load impedance 50mohm output capacitance typ. 2 050f included inside the power supply *) discharge current of output capacitors is not included. **) this is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. it is not guaranteed value which can be achieved. the typical value is about 28.5v. fig. 6-1 output voltage vs. output current, rms current, typ. fig. 6-2 intermittent operation at shorted output, typ. output voltage 0 024 4 8 12 28v 16 20 24 10a 531 67 intermittent operation 8 9 continuous current adjustment range output current a . . . 1 3 2 / 2 6 4 v a c b . . . 8 5 / 1 8 7 v a c a b 60ms 360ms 9.2a jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 6/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 7. h old - up t ime ac 100v ac 120v ac 230v hold-up time typ. 64ms 108 ms 105ms at 24v, 2.5a, see fig. 7-1 min. 54ms 91ms 88ms at 24v, 2.5a, see fig. 7-1 typ. 26ms 51ms 50ms at 24v, 5a, see fig. 7-1 min. 22ms 43ms 42ms at 24v, 5a, see fig. 7-1 fig. 7-1 hold-up time vs. input voltage fig. 7-2 shut-down behavior, definitions 0 25 50 125ms 85 120 155 190 230vac input voltage hold-up time 75 100 a) 24v 2.5a typ. b) 24v 2.5a min. c) 24v 5a typ. d) 24v 5a min. a b c d a b c d - 5% hold-up time zero transition output voltage input voltage 8. dc-ok r elay c ontact this feature monitors the output voltage, which is produced by the power suppl y itself. it is indepe ndent of a back-fed voltage from a unit connected in parallel to the power supply output (e.g. redundant application). contact closes as soon as the output voltage reaches 21.4v. contact opens as soon as the output voltage dips below 21.4v. contact ratings max. 60vdc 0.3a, 30vdc 1a, 30vac 0.5a resistive load min. 1ma at 5vdc minimum required load isolation voltage see dielec tric strength table in section 18. fig. 8-1 dc-ok relay contact behavior 21.4v open output voltage closed jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 7/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 9. e fficiency and p ower l osses ac 100v ac 120v ac 230v efficiency typ. 90.7% 91.2% 92.3% at 24v, 5a average efficiency *) typ. 89.2% 89.4% 90.6% 25% at 1.25a, 25% at 2.5a, 25% at 3.75a. 25% at 5a power losses typ. 1.4w 1.5w 0.7w at 24v, 0a typ. 7.0w 7.4w 6.0w at 24v, 2.5a typ. 12.3w 11.6w 10.0w at 24v, 5a *) the average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25% of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100% of the nominal load for the rest of the time. fig. 9-1 efficiency vs. output current at 24v, typ. fig. 9-2 losses vs. output current at 24v, typ. efficiency 0.5 86 87 88 89 90 91 92 85 93% 5a 2 2.5 4 13 a c b output current 1.5 3.5 4.5 a) 100vac b) 120vac c) 230vac power losses 0 15 a 0 2 6 8 10 12w 4 234 output current a) 100vac b) 120vac c) 230vac c b a fig. 9-3 efficiency vs. input voltage at 24v, 5a, typ. fig. 9-4 losses vs. input voltage at 24v, 5a, typ. efficiency 90 120 155 180 230 260vac 87 88 89 90 input voltage 91 92 93% power losses 6 8 10 12 14w 90 120 155 180 230 260vac input voltage jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 8/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 10. l ifetime e xpectancy and mtbf ac 100v ac 120v ac 230v lifetime expectancy *) 181 000h *) 194 000h *) 219 000h *) at 24v, 2.5a and 40c 511 000h *) 548 000h *) 621 000h *) at 24v, 2.5a and 25c 66 000h 68 000h 83 000h at 24v, 5a and 40c 188 000h *) 193 000h *) 234 000h *) at 24v, 5a and 25c mtbf **) sn 29500, iec 61709 1 065 000h 1 147 000h 1 379 000h at 24v, 5a and 40c 2 038 000h 2 166 000h 2 519 000h at 24v, 5a and 25c mtbf **) mil hdbk 217f 681 000h 651 000h 645 000h at 24v, 5a and 40c; ground benign gb40 872 000h 842 000h 839 000h at 24v, 5a and 25c; ground benign gb25 165 000h 164 000h 168 000h at 24v, 5a and 40c; ground fixed gf40 206 000h 205 000h 211 000h at 24v, 5a and 25c; ground fixed gf25 *) the lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. lifetime expectancy is specified in operational hours and is calculated acc ording to the capacitors manufacturer specification. the manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131 400h). any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices. **) mtbf stands for m ean t ime b etween f ailure, which is calculated according to statistical device failures, and indicates reliability of a device. it is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. the mtbf figure is a statistical representation of the likelihood of a device to fail. a mtbf figure of e.g. 1 000 000h means that statistically one unit will fail ev ery 100 hours if 10 000 units ar e installed in the field. how ever, it can not be determined if the failed unit has been running for 50 000h or only for 100h. 11. f unctional d iagram fig. 11-1 functional diagram + + - - v out input fuse & input filter output voltage regulator power converter output filter dc ok l n output over- voltage protection input rectifier & inrush limiter (ntc) dc-ok relay dc-ok contact 115/230v auto select jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 9/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 12. t erminals and w iring the terminals are ip20 finger sa fe constructed and suitable fo r field- and factory wiring. input and output dc-ok-signal type screw terminals push-in terminals solid wire max. 6mm 2 max. 1.5mm 2 stranded wire max. 4mm 2 max. 1.5mm 2 american wire gauge awg20-10 awg28-16 max. wire diameter 2.8mm (including ferrules) 1.6mm (including ferrules) wire stripping length 7mm / 0.28inch 7mm / 0.28inch screwdriver 3.5mm slotted or cross-head no 2 not required recommended tightening torque 1n m, 9lb.in not applicable instructions: a) use appropriate copper cables that are designed for minimum operating temperatures of: 75c for ambient up to 55c minimum and 90c for ambient up to 70c minimum. b) follow national installation c odes and installation regulations! c) ensure that all strands of a strande d wire enter the terminal connection! d) do not use the unit without pe connection. e) unused terminal compartments should be securely tightened. f) ferrules are allowed. jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 10/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 13. f ront s ide and u ser e lements fig. 13-1 front side a input terminals (screw terminals) n, l line input pe (protective earth) input b output terminals (screw terminals, two pins per pole) + positive output C ne gative (return) output c output voltage potentiometer guaranteed adjustment range: 24-28v factory set: 24.1v d dc-ok led (green) on, when the output voltage is >18v e dc-ok relay contact (push-in terminals) description see chapter 8 . jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 11/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 14. emc the power supply is suitable for applicat ions in industrial environm ent as well as in reside ntial, commercia l and light industry environment. a detailed em c report is available on request. emc immunity according generic standards: en 61000-6-1 and en 61000-6-2 electrostatic discharge en 61000-4-2 contact discharge air discharge 8kv 8kv criterion a criterion a electromagnetic rf field en 61000-4-3 80mhz-2.7ghz 20v/m criterion a fast transients (burst) en 61000-4-4 input lines output lines dc-ok signal (coupling clamp) 4kv 2kv 2kv criterion a criterion a criterion a surge voltage on input en 61000-4-5 l ? n l ? pe, n ? pe 2kv 4kv criterion a criterion a surge voltage on output en 61000-4-5 + ? - + / - ? pe 500v 1kv criterion a criterion a surge voltage on dc-ok en 61000-4-5 dc-ok signal ? pe 1kv criterion a conducted disturbance en 61000-4- 6 0.15-80mhz 20v criterion a mains voltage dips en 61000-4-11 0% of 100vac 40% of 100vac 70% of 100vac 0% of 200vac 40% of 200vac 70% of 200vac 0vac, 20ms 40vac, 200ms 70vac, 500ms 0vac, 20ms 80vac, 200ms 140vac, 500ms criterion a criterion c criterion a *) criterion a criterion c criterion a voltage interruptions en 61000-4-11 0% of 220vac (=0v) 5000ms criterion c voltage sags semi f47 0706 dips on the in put voltage according to semi f47 standard 80% of 208vac (166vac) 70% of 208vac (146vac) 50% of 208vac (104vac) 80% of 120vac (96vac) 70% of 120vac (84vac) 50% of 120vac (60vac) 1000ms 500ms 200ms 1000ms 500ms 200ms criterion a criterion a criterion c criterion a criterion a criterion c powerful transients vde 0160 over entire load range 750v, 1.3ms criterion a criterions: a: power supply shows normal operation behavior within the defined limits. c: temporary loss of function is possible. power supply may shut-down and restarts by itself. no damage or hazards for the powe r supply will occur. *) below 4.5a, criterion c for currents > 5a emc emission according generic standards: en 61000-6-3, en 61000-6-4 conducted emission input lines en 55011, en 55022, fcc part 15, cispr 11, cispr 22 class b conducted emission output lines **) iec/cispr 16-1-2, iec/cispr 16- 2-1 limits for dc power port according en 61000-6-3 not fulfilled radiated emission en 55011, en 55022 class b harmonic input current en 61000-3- 2 fulfilled for class a equipment voltage fluctuations, flic ker en 61000-3-3 fulfilled *) this device complies with fcc part 15 rules. operation is subjected to fo llowing two conditions: (1) this device may not cause ha rmful interference, and (2) this device must accept any interferenc e received, including interference that may cause undesired operation. *) tested with constant current loads, non pulsing **) for information only, not mandatory for en 61000-6-3 jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 12/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput switching frequency main converter 40khz to 120khz for load current range between 1a - 5a 15. e nvironment operational temperature *) -10c to +70c (14f to 158f) reduce output power according fig. 15-1 storage temperature -40c to +85c (-40f to 185f) for storage and transportation output de-rating 3w/c (55c to 70c; 131f to 158f) 3w/c (50c to 70c; 122f to 158f) for ac 110-120 / 220-240v mains systems ****) for ac 100 / 200v mains systems ****) humidity **) 5 to 95% r.h. iec 60068-2-30 vibration sinusoidal 2-17.8h z: 1.6mm; 17.8-500hz: 2g ***) 2 hours / axis ***) iec 60068-2-6 shock 30g 6ms, 20g 11ms ***) 3 bumps / direction, 18 bumps in total iec 60068-2-27 altitude 0 to 2000m (0 to 6 560ft) without any restrictions 2000 to 6000m (6 560 to 20 000ft) reduce output power or ambient temperature, see fig. 15-2 iec 62103, en 50178, overvoltage category ii altitude de-rating 7.5w/1000m or 5c/1000m > 2000m (6500ft), see fig. 15-2 over-voltage category iii iec 62103, en 50178, altitudes up to 2000m ii altitudes from 2000m to 6000m degree of pollution 2 iec 62103, en 50178, not conductive labs compatibility the unit does not re lease any silicone or other labs-criti cal substances and is suitable for use in paint shops. *) operational temperature is the same as the ambient or surrounding temperature and is defined as the air temperature 2cm bel ow the unit. **) do not energize while condensation is present ***) tested on a din-rail with a thickness of 1.3mm. ****) for ac 208v mains use ac 200-220v values. fig. 15-1 output current vs. ambient temp. fig. 15-2 output current vs. altitude 0 -10 0 +20 +40 +70c 1.0a 2.0a 4.0a 5.0a +55 allowable output current at 24v 3.1a 2.5a ambient temperature +50 a) ac 110-120/ 220-240v mains b) ac 100/ 200v mains a b allowed output current at 24v 0 0 2000 4000 6000m 1 2 3 4 5 6a altitude a . . . t a m b < 5 5 c b . . . t a m b < 4 5 c c . . . t a m b < 3 5 c a b c jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 13/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 16. p rotection f eatures output protection electronically protected against overload , no-load and short-circuits *) output over-voltage protection typ. 31vdc max. 34vdc in case of an internal pow er supply defect, a redundant circuit limits the maximum out put voltage. in such a case, the output shuts down and stays down until the input voltage is turned off and on again for at least one minute or until the green led went off. degree of protecti on ip 20 en/iec 60529 caution: for use in a contro lled environment according to csa 22.2 no 107.1-01. over-temperature protection no input transient protection mo v (metal oxide varistor) internal input fuse included not user replaceable *) in case of a protection event or in a low-load condition, audible noise may occur. 17. s afety f eatures input / output separation selv iec/en 60950-1 pelv iec/en 60204-1, en 50178, iec 62103, iec 60364-4-41 double or reinforced insulation class of protection i pe (protect ive earth) connection required isolation resistance > 100mohm input to output, 500vdc touch current (leakage current) typ. 0.21ma / 0.46ma 100vac, 50hz, tn-,tt-mains / it-mains typ. 0.30ma / 0.65ma 120vac, 60h z, tn-,tt-mains / it-mains typ. 0.33ma / 0.72ma 230vac, 50h z, tn-,tt-mains / it-mains < 0.27ma / 0.56ma 110vac, 50hz, tn-,tt-mains / it-mains < 0.38ma / 0.78ma 132vac, 60hz, tn-,tt-mains / it-mains < 0.43ma / 0.90ma 264vac, 50hz, tn-,tt-mains / it-mains jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 14/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 18. d ielectric s trength the output voltage is floating and has no ohmic connection to the ground. type and factory tests are conducted by the manufacturer. field tests may be c onducted in the field using the appropria te test equipment, which applies the voltage with a slow ramp (2s up and 2s down). connect all input-terminals togeth er as well as all ou tput poles before conducting the test. when testing, set the cut-off current settings to the value in the table below. fig. 18-1 dielectric strength a b c d type test 60s 2500vac 3000vac 1000vac 500vac factory test 5s 2500vac 2500vac 500vac 500vac field test 5s 2000vac 2000vac 500vac 500vac cut-off current setting > 10ma > 10ma > 15ma > 1ma ad c b b *) n l input dc-ok earth, pe output - + b*) when testing input to dc-ok ensure that the max. voltage between dc-ok and the output is not exceeded (column d). we recommend connecting dc-ok pins and the output pins together when performing the test. to fulfil the pelv requirements a ccording to en60204- 1 6.4.1, we recommend that either the + pole, the C pole or any other part of the output circuit shall be conne cted to the protective earth system. this helps to avoid si tuations in which a load starts unexpectedly or can not be swit ched off when unnoticed earth faults occur. jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 15/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 19. a pprovals ec declaration of conformity the ce mark indicates conformance with the - emc directive 2004/108/ec and the - low-voltage directive (lvd) 2006/95/ec iec 60950-1 2 nd edition, planned cb scheme, information technology equipment ul 60950-1 2 nd edition, planned recognized for use as information technology equipment, level 5; u.s.a. (ul 60950-1) and canada (c22.2 no. 60950-1); e-file: e137006 applicable for altitudes up to 2000m. ul 508, planned ind. cont. e q. listed for use as industri al control equipment; u.s.a. (ul 508) and canada (c22.2 no. 107-1-01); e-file: e198865 eac tr registration registration for the eurasian customs union market (russia, kazakhstan, belarus) 20. r o hs, reach and o ther f ulfilled s tandards rohs directive directive 2011/65/eu of the european parliament and the council of june 8 th , 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. reach directive directive 1907/2006/eu of the european parliament and the council of june 1 st , 2007 regarding the registration, evaluation, authorisation a nd restriction of chemicals (reach) jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 16/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 21. p hysical d imensions and w eight width 39mm 1.54 height 124mm 4.88 depth 124mm 4.88 the din-rail height must be added to the unit depth to calculate the total required installation depth. weight 370g / 0.81lb din-rail use 35mm din-rails according to en 60715 or en 50022 with a height of 7.5 or 15mm. plastic material of housing flame re tardant polycarbonate (pc) - ul94-v0 vicat softening temperature specified with 149c according to astm d1525 installation clearances see chapter 2 fig. 21-1 front view fig. 21-2 side view jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 17/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 22. a ccessory 22.1. uf20.241 b uffer module this buffer unit is a supplementary device for dc 24v power supplies. it delivers power to bridge typi cal mains failures or extends the hold-up time after turn-off of the ac power. in times when the power supply provides sufficient voltag es, the buffer module stores energy in integrated electrolytic capaci tors. in case of mains volt age fault, this energy is released again in a regulated process. one buffer module can deliver 20a which can also be used to supp ort peak current demands. the buffer unit does not require any control wiring. it can be a dded in parallel to the load circuit at any given point. buffer units can be added in parallel to increase the output ampacity or the hold-up time. dc buffer unit(s) power supply load ac + - 22.2. yr2.diode r edundancy m odule the yr2.diode is a dual redundancy modu le, which has two diodes with a common cathode included. it can be used for various purposes. the most popular applicat ion is to configure highly reliable and true redundant power supply systems. another interesting application is the separation of sensitive loads from non- sensitive loads. this avoids the distortion of the power quality for the sensitive loads which can cause controller 18/22 failures. see chapter 23.5 for instructions how to d a redundant system. failure monitor 24v,5a load i i l n pe yr2.diode redundancy module + - out + - in 1 + - in 2 l n pe pic120.241d power supply 24-28v dc-ok dc- ok + + - - l n pe pic120.241d power supply 24-28v dc-ok dc- ok + + - - buil jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 23. a pplication n otes 23.1. p eak c urrent c apability the unit can deliver peak currents (up to several milliseconds) which are higher than the sp ecified short term currents. this helps to start current demanding loads. solenoids, contactors and pneumatic modules often have a steady state coil and a pick-up coil. the inrush current demand of the pick-up coil is several times higher than the steady-state current and usually exceeds the nominal output current. the same situation applies when sta rting a capacitive load. the peak current capability also ensures the safe operati on of subsequent circuit breakers of load circ uits. the load branches are often individually protected with circuit breakers or fuses. in ca se of a short or an overload in one branch circuit, the fuse or circuit breaker need a certain amount of over-current to open in a timely manner. this avoids voltage loss in adjacent circuits. the extra current (peak current) is supplie d by the power converter and the built -in large sized output capacitors of the power supply. the capacito rs get discharged during such an event, which causes a vo ltage dip on the output. the following two examples show typical voltage dips: fig. 23-1 peak load with 2x the nominal current for 50ms, typ. fig. 23-2 peak load with 5x the nominal current for 5ms, typ. 10ms/div output voltage output current 24v 0a 10a 17v 1ms/div output voltage output current 24v 0a 25a 9v 10a peak load (resistive) for 50ms output voltage dips from 24v to 17v. 25a peak load (resistive) for 5ms output voltage dips from 24v to 9v. peak current voltage dips typ. from 24v to 17v at 10a for 50ms, resistive load typ. from 24v to 13v at 25a for 2ms, resistive load typ. from 24v to 9v at 25a for 5ms, resistive load 23.2. b ack - feeding l oads loads such as decelerating motors and induc tors can feed voltage back to the power supply. this feature is also called return voltage immunity or resi stance against back- e.m.f. ( e lectro m agnetic f orce). this power supply is resistant and does not show malfunctioning when a load f eeds back voltage to the power supply. it does not matter whether the power supply is on or off. the maximum allowed feed-back- voltage is 35vdc. the absorbin g energy can be calculated according to the built-in large sized output capacitor wh ich is specified in chapter 6 . jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 19/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 23.3. e xternal i nput p rotection the unit is tested and approved for bran ch circuits up to 30a (ul) and 32a (i ec). an external protection is only required if the supplying branch has an ampacity greater than this. check also local codes and local requirements. in some countries local re gulations might apply. if an external fuse is necessary or utilized, minimum requirements need to be considered to avoid nuisance tripping of the circuit breaker. a mi nimum value of 10a b- or 6a c-cha racteristic breaker should be used. 23.4. p arallel u se to i ncrease o utput p ower do not use the power supply in pa rallel to increase the output power. 23.5. p arallel u se for r edundancy power supplies can be paralleled for redundancy to gain higher system availability. redundant systems require a certain amount of extra power to support the load in case one power supply unit fails. the simplest way is to put two power supplies in para llel. this is called a 1+1 redundancy. in case one power supply unit fails, th e other one is automatically able to support the load current without any interruption. failure monitor 24v,5a load i i l n pe yr2.diode redundancy module + - out + - in 1 + - in 2 l n pe pic120.241d power supply 24-28v dc-ok dc- ok + + - - l n pe pic120.241d power supply 24-28v dc-ok dc- ok + + - - please note: this simple way to build a redundant system does not cover failures such as an internal s hort circuit in the secondary side of the power supply. in such a case, th e defect unit becomes a load for the other power supplies and the output vo ltage can not be maintained any more. this can only be avoided by utilizing decoupling diodes which are included in the redundancy module yr2.diode. recommendations for building redundant power systems: a) use the dc-ok signal contact to monitor the individual power supply units. b) use separate input fuses for each power supply. c) use separate mains syste ms for each power supply whenever it is possible. d) it is desirable to set the output voltages of all units to the same value ( 100m v) or leave it at the factory setting. jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 20/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput 23.6. s eries o peration unit a ac dc unit b ac dc - + - + load + - earth (see notes) power supplies of the same type can be connected in series for higher output voltages. it is possible to connec t as many units in series as needed, providing the sum of the output volt age does not exceed 150vdc. voltages with a potential above 60vdc are not selv any more and can be dangerous. such voltages must be installed with a protection against touching. earthing of the output is required when the sum of the output voltage is above 60vdc. avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the output terminals. keep an installation clearance of 15mm (left / right) be tween two power supplies and avoid installing the power supplies on top of each other. pay attention that leakage current, emi, inrush current, ha rmonics will increase when usin g multiple power supplies. 23.7. i nductive and c apacitive l oads no limitations for inductive loads no limitations for capacitive loads in combinat ion with an additional resistive type of load. limitations apply for capacitive loads in combination with con stant current type of loads: - max. 20mf with an additional 2.5a constant current load and - max. 10mfwith an additional 5a constant current load. 23.8. c harging of b atteries do not use the power supply to charge batteries. jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 21/22
pic120.241d piano-series 24v, 5a, s ingle p hase i nput jun. 2016 / rev. 1.2 ds-pic120.241d-en all parameters are specified at 24v, 5a, 230vac, 50hz, 25c ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com phone +49 89 9278 0 germany 23.9. o peration on t wo p hases 240v +10% max. fuse l2 l1 l3 l n pe power supply ac dc internal fuse the power supply can also be used on two-phases of a three-phase-system. such a phase-to-phase connection is allowed as long as the supplying voltage is below 240v +10% . 23.10. u se in a t ightly s ealed e nclosure when the power supply is installed in a tightly sealed encl osure, the temperature inside the enclosure will be higher than outside. in such situations, th e inside temperature defi nes the ambient temperatur e for the power supply. the following measurement results can be used as a reference to estimate the temperature rise inside the enclosure. the power supply is placed in the middle of the box ; no other heat producing items are inside the box. enclosure: rittal type ip66 box pk 9516 100, plastic, 110x180x165mm input: 230vac case a: load: 24v, 5a; load is placed outside the box temperature inside the box: 41.5c (in the middle of the right side of the pow er supply with a distance of 1cm) temperature outside the box: 24.4c temperature rise: 17.1k case b: load: 24v, 4a; (=80%) load is placed outside the box temperature inside the box: 38.9c (in the middle of the right side of the pow er supply with a distance of 1cm) temperature outside the box: 24.2c temperature rise: 14.5k 22/22


▲Up To Search▲   

 
Price & Availability of PIC120241D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X